Warranty: | One Year |
---|---|
Certification: | CE, ISO9001 |
Condition: | New |
Maximum Lifting Weight: | 10t |
Installation: | Assembled |
Moving Type: | Fixed |
Customization: |
---|
Suppliers with verified business licenses
Power supply | DC24V | power | 20W |
Lifting resolution | 0.1t | Alarm error | <3% |
Protection | IP65 | Standards | GB7950-99 |
screen resolution | 1024*600 | screen size | 7 inch |
LMI dimension | 305 mm *182 mm *71.6mm | ||
Error (Code) | Cause | Action |
SLI/LMI no display |
|
Check power supply and cables. |
Load display as '0' |
|
|
Load value display instability |
|
|
Control no response |
|
|
E11/E31 |
Fallen below lower limit value for the measuring channel voltage "Angle/Length". | Check cables as well and Length/Angle transducers. |
E12/E32 | Upper limit value for the measuring channel voltage "length/angle" exceeded. | Check cables as well and Length/Angle transducers. |
E21 | Fallen below lower limit value for the measuring channel voltage "Load". | Check cables as well and load cell. |
E22 | Upper limit value for the measuring channel voltage "Load" exceeded. | Check cables as well and load cell. |